7-55
33
11
UOUO
22
1818
Bell Stay Off
The switch output is activated as follows:
• If the system is activated externally (AWAY), the switch output is activated
as soon as the sounder is triggered in the selected area.
• If the system is activated internally (STAY), the switch output is not
activated if the sounder is triggered in the selected area.
NOTE:
If an alarm is to be triggered in a zone that is assigned to more than one area, and if one of
the areas is in an externally activated state (while the other area is in an internally activated
state), the switch output is activated in the event of an alarm.
In an internally activated state, a 24-hour zone does not activate this switch output.
33
11
UOUO
22
1919
Zone Bypass
The switch output is activated if a zone is omitted in the selected area(s) and the area(s)
are internally or externally activated.
33
11
UOUO
33
Follow Zone
This menu option lists events for a zone.
33
11
UOUO
33
11
Zone Follow
The switch output is activated if the selected zone is triggered. The state of the alarm
system is not relevant.
33
11
UOUO
33
22
Alarm Follow
The switch output is activated as soon as the selected zone triggers an alarm.
33
11
UOUO
33
33
Arm Follow
The switch output is activated if the selected zone is triggered via the system.
33
11
UOUO
33
44
Disarm Follow
The switch output is activated if the selected zone is deactivated via the system.
33
11
UOUO
44
Follow User Code
The switch output is activated if a valid user code is entered.
The switch output is activated by the user in the function menu Activities/Operate Output,
buttons [2][1].
To enable you to activate the output with a PIN, the PIN must be authorised for the
activation of a switch output.
Press or to select the equivalent code from the 32 available user codes.
Press to switch between [Y] YES and [N] NO.
NOTE:
The switch output is activated by the entry of a user code only if the utility output setting is
set to N in the system macros. If quick output is activated, no user code is required.
33
11
UOUO
22
2020
Auto Arm Alarm
The switch output is activated if an alarm was activated during the prewarning time during
an auto-arm process.
33
11
UOUO
22
2121
Zone Loss Alarm
The switch output is activated if a wireless zone is lost.