7-25
7.2.2
11
22
System Control
Under System Control, you make settings that control specific functions of the complete system.
NOTE:
Under this menu item, it is important that you press the lozenge button before exiting so that your data is saved. If you
exit the menu by pressing , your settings are lost.
To access the System Control menu option:
1. Select the main menu System as described on page 7-23.
2. In the System menu, press
22
to get to System Control. You see the following on the display:
3. Select and configure the settings in the System Control menu as follows:
System Control:
Quick-Key Parameter Default Range
11
22
0101
Quick arm
ES
YES/NO
ES: No user PIN is necessary for activating the system or an area.
NO: A user PIN is necessary for activating the system or an area. Choose this setting if
the alarm system or an operating panel is accessible to the public or to children.
11
22
0202
Quick UO
ES
YES/NO
ES: A user can activate a switch output without a user PIN.
NO: A user PIN is necessary to activate a switch output.
11
22
0303
Allow Bypass
ES
YES/NO
ES: A zone can be omitted (excluded from surveillance) by an authorised user.
NO: Omitting zones from surveillance is not possible.
11
22
0404
Quick Bypass
NO
YES/NO
ES: No user PIN is required for omitting a zone.
NO: A user PIN is required for omitting a zone.
11
22
0505
False Code Trouble
ES
YES/NO
ES: If an incorrect user PIN is entered three times, the operating panel is locked and, if
programmed, an alarm is sent by telephone. Bad PIN input is displayed as a fault on
the operating panel.
NO: If an incorrect user PIN is entered three times, the operating panel is locked and a
local alarm is sounded.