14 Configuration of the web server
25
14.3.1 RF-Inputs
1. Name: Name of the zone/specification whose name is used in the zone
display in the “Overview” menu.
2. Bypass (on/off): The selected zone is hidden (i.e. zones can be deactivated).
This function can be used to bypass specific zones and their detectors, when
necessary (e.g. when the detector indicates an empty battery or a detector in
the zone cannot be connected). The bypass is only activated for one arming
procedure, and is then automatically reset.
3. Internal activation: Using the internal activation setting, you can define
whether the affected zone is monitored by internal activation of the alarm
centre. To enable the zone to be internally activated, the regulator must be put
to “On”. After internal activation, only the monitored zones are shown in the
overview. All the remaining zones are deactivated in this mode and displayed
in grey.