10 Display and setting elements
11
10. Display and setting elements
10.1 Display LEDs
The display consists of 10 LEDs
Green LED (“Power” LED) for monitoring the power supply
Permanently lit: Power supply is OK
Flashing with 1 Hz: Mains power supply failure; only indicated if a
backup battery is in use.
Red LED (“Trouble” LED) for displaying faults
Off: No faults
Flashing with 1 Hz: Supervision fault (detector or device is
indicated by the channel LED flashing with 1 Hz. If only this LED
flashes, this indicates that the alarm centre itself has been
tampered with).
Permanently lit: Indicates jamming.
Blue LEDs (“Channel” LEDs) for detector status display
Off: Detector OK (closed)
Permanently lit: Detector is open or has triggered (open);
operating units are lit briefly indicating that a wireless signal has
been received.
Flashing with 5 Hz: Empty battery on a wireless component
Flashing with 1 Hz: Wireless component has been tampered
Bottom blue LED lights up: Indicates that this refers to the second
caption level (i.e. channels 8–14).
10.2 LED table
Layer 1 Layer 2
Zone 1
Lights up/
flashes
Channel 7
Lights up/
flashes
Channel 14
Zone 3
Lights up/
flashes
Channel 6
Lights up/
flashes
Channel 13
Lights up/
flashes
Channel 5
Lights up/
flashes
Channel 12
Lights up/
flashes
Channel 4
Lights up/
flashes
Channel 11
Operating
units
(Secvest Key
remote control)
Lights up/
flashes
Channel 3
Lights up/
flashes
Channel 10
Zone 2
Lights up/
flashes
Channel 2
Lights up/
flashes
Channel 9
Lights up/
flashes
Channel 1
Lights up/
flashes
Channel 8
Does not light up Lights up